A31 Latest refrigeration and air-conditioning technology of next-generation low GWP refrigerants 1 09:40 〜 10:40 |
|
---|---|
A311 |
Next Generation Low-GWP Refrigerant "AMOLEA"
|
A312 |
Evaluation of Reaction Inhibitors for the Disproportionation Reaction of HFO-1123
|
A313 |
Experiment on Condensation Heat Transfer of Binary Mixture of R32+R1123 in Multiport Tubes
|
A32 Latest refrigeration and air-conditioning technology of next-generation low GWP refrigerants 2 11:10 〜 12:10 |
|
---|---|
A321 |
Development of Assessment Techniques for Next-Generation Refrigerant with Low GWP Values
2nd Report: Efforts and Outcomes of FY2019 |
A322 |
Development of Assessment Techniques for Next-Generation Refrigerant with Low GWP Values
Third report: Simulator development |
A323 |
Industrial Refrigeration Systems by Natural Refrigerants
|
A33 Utilization Technology of Ground Source Heat 1 13:30 〜 14:50 |
|
---|---|
A331 |
Study on Installation Effect of Ground Source + Air Source Hybrid air Conditioning System
|
A333 |
Performance Evaluation of New Ground Heat Exchangers by Using Computer Fluid Dynamics
|
A334 |
Performance Evaluation Method for Ground Heat Exchangers by using Measurement Data in Ground Source Heat Pump Systems
|
A34 Utilization Technology of Ground Source Heat 2 15:20 〜 17:00 |
|
---|---|
A341 |
Evaluation Method of Soil Thermal Property for Shallow Ground Thermal Energy Utilization
|
A342 |
Estimation of Groundwater Flow in Multilayer using the Distributed Temperature Sensors and the Long-term GSHP Performance Evaluation
|
A343 |
Air Conditioning Performance of a Ground Source Heat Pump that use Direct Expansion Method
|
A344 |
Hot water Supply Performance of a Ground Source Heat Pump that Use Direct Expansion Method
|
A345 |
Study on Ground Source Heat Pump using Steel Pipe Pile for House
|
B31 Technological Development in Heat Exchangers 6 09:20 〜 10:40 |
|
---|---|
B311 |
Attempt to Measure Heat Transfer Fluctuation through a Visible-light Transparent Heater by Infrared Thermography
|
B312 |
Arrangement of Pressure Drop Characteristics of Sintered Fibrous Porous Tube using Permeability and Tube Friction Coefficient
|
B313 |
Reduction Effect of Heat Conduction Resistance of Airfoil-shaped Tube with Slitted Extended Section Heat Exchanger by Bridges
|
B314 |
Boiling Heat Transfer Characteristics of Ammonia in Plate Heat Exchanger using Flat Aluminum Plate
|
B32 Technological Development in Heat Exchangers 7 11:10 〜 12:30 |
|
---|---|
B321 |
Experimental Study on Boiling and Condensation Heat Transfer of R1234yf Inside a Plate Heat Exchanger
|
B322 |
Visualization of Temperature Distribution of Heating Medium and Refrigerant Flow in Plate-fin Evaporator
- Effect of flow direction of heating medium - |
B323 |
Experiment on Evaporation Heat Transfer of R1234ze(E) in a Plate-Fin Heat Exchanger
|
B324 |
Boiling Heat Transfer Characteristics of Ammonia in Plate Heat Exchanger using Herringbone Aluminum Plate
|
B33 Performance Evaluation of Refrigerators, Air-conditioners and Heat Pump Water Heaters 1 13:30 〜 14:50 |
|
---|---|
B331 |
Development of DC Outdoor Unit
|
B332 |
Dynamic Cycle Simulation of Vapor-compression Type Air-conditioning Systems using Zeotropic Refrigerant Mixture
Cycle simulation based on hierarchical solution method |
B333 |
Experimental Study on Air- conditioning and Ventilation Systems assuming Mass Ventilation
Measurement of CO2 concentration and ventilation experiment at condominium and university lecture room |
B334 |
Experimental Study on Air- conditioning and Ventilation Systems assuming Mass Ventilation
Long-term continuous measurement of indoor air quality in small size business building |
B34 Performance Evaluation of Refrigerators, Air-conditioners and Heat Pump Water Heaters 2 15:20 〜 17:00 |
|
---|---|
B341 |
Performance Evaluation of CO2 Heat Pump Water Heater in a Tropical Climate
Field test at a hair salon in Singapore |
B342 |
Study on Performance Evaluation of CO2 Water Source Heat Pump to Water Heating System for Residential Purposes
|
B343 |
Performance Evaluation of Low GWP Refrigerant as a Drop-in Replacement for R410A in Room Air Conditioner by EnergyFlow+M
|
B344 |
Study on Unsteady-state Characteristics and Consideration of Control of Vapor Compression Heat Pumps
1st Report: Unsteady-state characteristics at partial load |
B345 |
Performance Evaluation by Simulation of Refrigerated Display Cabinets using HFO Refrigerant
1st report: Performance evaluation by simulation |
C31 Refrigeration Cycle Control 1 09:40 〜 10:40 |
|
---|---|
C311 |
Development of Refrigerant Distributor with Slitted Pipes
1st Report: Principle verification by prototype distributor |
C312 |
Development of Refrigerant Distributor with Slitted Pipes
2nd Report: Performance comparison between the prototype and the current distributer |
C313 |
Study on Improvement of Defrosting Operation Performance in Multi-split Type Air-conditioning System for Buildings
|
C32 Refrigeration Cycle Control 2 11:10 〜 12:30 |
|
---|---|
C321 |
Study on Consideration of Direct Expansion System for Environmental Laboratory
Part 3: Temperature control precision when the air volume changes |
C322 |
Positive Pressure Control Device to Save Energy of the Whole Store for Convenience Store
|
C323 |
Research and Development of Remote Refrigerant Leak Monitoring System for VRF Systems
The 2nd Report - Development of automatic refrigerant leak detection method using machine learning - |
C324 |
Evaluation of Performance of DR Control using VRF Type air Conditioner as Energy Resources
|
C33 Heat Pump and Energy Harvesting 1 13:30 〜 14:50 |
|
---|---|
C331 |
Giant Anomalous Nernst Effect due to Topological Electronic Structure
|
C332 |
Operational Situation - 2MW Woody Biomass Gasification Power Plant
|
C333 |
Effective Power Utilization Technique of Renewable Energy by using Hydrogen Conversion System
|
C34 Heat Pump and Energy Harvesting 2 15:20 〜 17:00 |
|
---|---|
C341 |
Regenerate Waste Heat from the Heat Pump
|
C342 |
Overview of Virtual Power Plant Project in Toyota City
|
C343 |
Demonstration Project on Automated Demand Response with Air Conditioning System and IoT technology in the Portuguese Republic
Final report - Interim Report of the Project – |
C344 |
Developing High Efficiency Centrifugal Chillers with the Power Recovery/Power Generation Function
|